SUPERIORJW Diner Q-SYS Programming Portal

JW Marriott DC Diner, Q-SYS programming. Tick each step as you finish it. Your ticks save on this phone only.

· Built from playbook.md + open-questions.md (11/11/2026).

JW Marriott DC Diner: Q-SYS Field Programming Playbook

For: Lorenzo Snead (Phoenix Technologies), on site at the rack, 1331 Pennsylvania Ave NW
Prepared: Wed 11/11/2026 (PT) by Superior Connects ops.
Sources: Superior "JW Diner Q-SYS Design Plan 2026-11-09" (the Plan), EMD/W-T "JWDC AV Programming Spec 2.4" (the Spec), Creation Networks order emails, and the official Q-SYS docs linked in each step.

Rules for this page

CHECK ON SITE = we can't know it from here. Read it off the hardware, Configurator or Core Manager.
TBD (Plan) = still open in our design plan. Use the placeholder and note what you actually did.
We never guess IPs, names or counts. Use the IP assigned by the building/Whiting-Turner IT; do not use an example address.

0 Quick read: the 3 Cores (decide this first)

Hardware on order: 3x Core 8 Flex (CN8699), 1x QIO-ML4i, 1x QIO-L4o, QIO-IR1x4 (confirm on site whether it is present), TSC-50-G3 touch screens (count the TSC panels installed: plan shows 4, orders show 5), 3x Lab Gruppen E 5:4, 5x RDL DD-BN31 Dante plates, 1+ Netgear M4250-26G4F-PoE+, and 1 iPad Air.

Recommendation (simplest valid setup): ONE design on ONE Core.

Why not 3 separate Cores, one per zone? It would be valid Q-SYS, but it's the wrong fit here:

Why not a redundant pair today? Core 8 Flex does support Core redundancy (set Is Redundant = Yes and name the Backup Core). However, Flex outputs cannot be wired redundantly, both Cores must be online during install, and the Core Redundancy network service has to be enabled on both. (Core Redundancy) That's extra complexity we don't need to get sound working today. Revisit only if EMD or Dana asks for it.

How to tell which mode each unit is in:

A Before you start (10-minute checklist)

Open questions (JWDC Diner Q-SYS: Questions only Lorenzo can answer on site)

From open-questions.md. Tick each once you have the answer; these ticks don't count toward progress.

Type your answers and send them (section J)

(Ask these first. Each answer changes a step in playbook.md.)

1. What exactly is failing? (pick the step)

2. Versions

3. The 3 Core 8 Flex units

4. Speakers and amps

5. Inputs and sources

6. Touch screens, iPad, IR

7. Network

8. Fire alarm

9. Still TBD in our Plan (not Lorenzo's problem today)

B Find the hardware (Configurator + Core Manager)

C Build the design (this job)

Build the full 3-zone design now and enable Phase 1 speakers only. Pre-build the Phase 2 chains (including AMP-3) and keep the Phase 2 UCI controls hidden or disabled (Plan §1.2 / §8).
Zones (Proposal §2.1): Diner & Bar (16 spk design), Private Dining (4), Restaurant & Lounge (33).
Which zones the 18–20 installed Phase 1 speakers serve is TBD (Plan §1.2). Ask yourself first, and do not assume 16+4=20.

C1. Inventory

C2. Schematic per zone (repeat x3)

Make one schematic page per zone (left pane Schematic Pages). Components come from the Schematic Library on the right; use its search box. Connect output pins to input pins by dragging wires. Use Signal Names to link between pages (Getting Started).

Chain per zone (Plan §7):

C3. Fire-alarm input to system mute

Per the Q-SYS KB (Fire Alarm Relay with Digital TTL) and GPIO In (Core 8 Flex):

C4. Master on/off and 4:00 AM reset (Spec 2.4.A.3.3 and .11)

C5. QIO-IR1x4 (only if it's on site)

C6. Check it

D UCIs (touch screens + iPad)

E Deploy, test, and back up

F Test & commission (per zone, against Spec 2.4)

Run all of this per zone: Diner & Bar / Private Dining / Restaurant & Lounge. Phase 2 zones: only the UCI behavior can be checked.

G Troubleshooting

Core not in Configurator
Likely cause Laptop on the wrong port/VLAN, Wi-Fi taking the route, or multicast blocked
Fix (doc) Plug into the AV switch, NIC on DHCP, Wi-Fi off. Still missing: add a Hard Link to the Core IP. Note that Hard Links only help Designer and UCI Viewer; the Core still needs multicast to reach its peripherals (Initial Discovery, Hard links FAQ)
Core shows RED in Configurator
Likely cause Laptop not on the Core's subnet (static IP elsewhere)
Fix (doc) Read the IP on the front panel (Next) and set the laptop to a free IP in that subnet (Configurator)
Devices appear, then disappear
Likely cause IGMP snooping without a querier, or querier/snooping timers mismatched
Fix (doc) Apply the Netgear Q-SYS profile, or set exactly one IGMPv2 querier. As a test, disable IGMP snooping (Configurator troubleshooting, Switches)
F5 stuck on "Discovering Core…"
Likely cause Design Core Name/Model ≠ physical Core
Fix (doc) Copy the exact hostname from Core Manager; Model = Core 8 Flex (Connecting to the Core)
Peripheral "Missing" (red) in Inventory/Status
Likely cause Name in design ≠ hostname, wrong model component, device offline, or an I/O-Core 8 Flex that is still in Core mode
Fix (doc) Match names exactly (ID button to confirm). Check PoE/link. Check the mode (section 0). "Missing = device cannot be discovered" (Status I/O-Core 8 Flex)
"Not Present"
Likely cause Is Required = No and device not found, or Dynamic Pairing unassigned
Fix (doc) Same as above. Set Is Required = Yes so faults show
"Initializing" for a long time
Likely cause Firmware update in progress after F5
Fix (doc) Wait, it can take a while. Don't power-cycle mid-update (Installing & Updating)
Firmware mismatch prompt
Likely cause Designer ≠ Core firmware
Fix (doc) Click Update, or install the Designer version that matches the Core (Updating Firmware KB)
Can't Save to Core / Load from Core: credentials
Likely cause Core Manager Access Control is on
Fix (doc) Log in with an Administrator or Technician role (who set it? CHECK ON SITE) (8.4 release notes)
No audio out of an amp
Likely cause System Mute on, zone mute, Router on "Off", Flex channel set as input not output, cable to the wrong amp input, amp attenuator down, amp in standby (GPI open, or the E-Series auto-standby after about 20 min with no signal per its manual: verify), amp mode not 70 V, idle design
Fix (doc) Work along the chain: meter at the QIO/Flex out → amp input LED → amp output. Check the Status page. Use a Noise Generator. The E 5:4 doesn't show in Q-SYS, so check it at the amp
Audio "Compromised – Packet Missing / Too Late" on Q-LAN/AES67 receivers
Likely cause QoS/PTP problem, cabling or CRC errors, EEE on
Fix (doc) DSCP: EF 46 highest, AF41 34 second, Strict Priority. EEE off. Check port error counters (Switches, KB Packet Missing)
Dante plates not heard
Likely cause Software Dante not started or not routed, mDNS service off, channel count over 8
Fix (doc) Enable the Core Manager Network Services discovery, set External Config/Control = Yes, route in Dante Controller (Software Dante TX)
TSC shows "Fault – No UCI assigned" or the Inventory Status page
Likely cause UCI field blank, TSC name mismatch
Fix (doc) Assign the UCI (Static), match the hostname, F5 again (KB)
UCIs won't deploy (license)
Likely cause Core on 9.x without a UCI Deployment license
Fix (doc) Upgrade the design/Core to 10.x, where UCI is free on any Core (FAQ)
iPad can't find the Core/UCI
Likely cause iOS multicast limits, UCI Viewers service off, Local Network permission off, filters set, iPad Wi-Fi can't route to the Core
Fix (doc) Add a Hard Link IP, enable the "Q-SYS UCI Viewers – Windows and iOS" service, check iPad Settings > Q-Sys Control (UCI Viewer iOS)
iPad shows the UCI but touches don't respond
Likely cause App bug reported by users on 10.4
Fix (doc) Try toggling UCI Viewer Mode, test from Core Manager > UCI View, call support (App Store review, not official)
QIO unreachable after a bad IP setting
Likely cause Static IP typo
Fix (doc) QIO short reset: about 10 s, release before 20 s (QIO-L4o)

H Escalation (call early; it's free)

I Q-SYS Training pages (read only what you need)

These are Q-SYS Training pages, not videos. Some may need a free Q-SYS account sign-in.

Level Zero – Software Basics
Length short
Covers Workspace, panes, modes
Link view
Level Zero – The Inventory Panel
Length ~7 min
Covers Core name/model, adding QIOs/TSCs, Status components
Level Zero – Connecting to the Core
Length ~7.5 min
Covers Configurator, Core Manager naming, F5, "Discovering Core…"
Link view · print
Level 1 – UCI Creation and Management
Length ~10 min
Covers New UCI, Panel Type, pages, navigation, Private, PIN logon
Link view · print
Level 1 – UCI Deployment
Length ~7 min
Covers Assigning a UCI to a TSC, Static/Dynamic, iPad/Windows viewers, UCI Viewer component
Link view · print
Fire alarm GPIO example (KB)
Length read
Covers GPIO in → System Mute, Logic NOT
Link KB

J Answer these on site

Don't enter passwords or logins here.

Tapping Send answers emails everything below (and your photos) to Superior Connects at info@superiorconnects.com through FormSubmit. Your typing is also saved on this phone until you clear it.

1. What exactly is failing? (pick the step)
2. Versions
3. The 3 Core 8 Flex units
4. Speakers and amps
5. Inputs and sources
6. Touch screens, iPad, IR
7. Network
8. Fire alarm

Don't enter passwords or logins here.